Overview
Epsilon 1 will be pre-calibrated in the factory for analyzing of Pt, Pd and Rh in spent automotive catalytic convertors. Put loose powder in a sample cup and measure directly.
The accuracy of the method is validated by measuring Certified Reference Materials. The results clearly demonstrate the capability of Epsilon 1 for the analysis of valuable precious metals Pt, Rh and Pd in catalytic converters.
Sample name (repeats) | Compounds | Certified conc. | Average conc. | RMS | Rel. RMS (%) |
---|---|---|---|---|---|
NIST 2556 (20x) | Pt (ppm) | 697.4 +/- 6.3 | 695.6 | 7.2 | 1.1 |
Rh (ppm) | 51.2 +\- 0.5 | 53.9 | 2.0 | 3.7 | |
Pd (ppm) | 326 +/- 1.6 | 322.8 | 7.2 | 2.2 | |
NIST 2557 (20x) | Pt (ppm) | 1131 +/- 1.9 | 1189.6 | 13.2 | 1.1 |
Rh (ppm) | 135.1 +/- 1.9 | 141.6 | 2.2 | 1.6 | |
Pd (ppm) | 233.2 +/- 1.9 | 236.9 | 3.6 | 1.5 | |
ERM-EB504a (5x) | Pt (ppm) | 1414 +/- 9.0 | 1424.8 | 5.1 | 0.4 |
Rh (ppm) | 210 +/- 2.2 | 216.2 | 2.3 | 1.1 | |
Pd (ppm) | 1596 +/- 11 | 1675.1 | 18.3 | 1.1 | |
FLX 133 (5x) | Pt (ppm) | 465 +/- 32 | 462.1 | 4.0 | 0.9 |
Rh (ppm) | 242 +/- 4 | 237.6 | 4.0 | 1.7 | |
Pd (ppm) | 1075 +/- 33 | 1093.8 | 15.3 | 1.4 |
Features
Factory calibrated |
Operator friendly |
X-ray shielded |
High level of trust |
Guaranteed maximum safety
All Malvern Panalytical X-ray solutions are designed according to the strict regulations of regulatory bodies. The Epsilon 1 tabletop system shields its users against X-rays during analysis.
You’ll have peace of mind in the lab thanks to a unique internal interlocked enclosure providing complete radiation protection, deserving its Vollshutz classification. No need to worry about safety as the system is fully enclosed and completely safe.

Be Flexible
Sometimes, it’s just not possible or worthwhile to calibrate all your sample types. Perhaps there are no standards, or those that are available are too expensive. But you can still use a generic method to analyze the elemental composition of a single sample. Even better – this method is available on our Epsilon 1 XRF benchtops.
How does this work? By using our standardless Omnian software! Combining twenty generic samples with the power of physics, Omnian can quantify elemental composition for a wide variety of sample types – including polymers and liquids.

內建完整系統
內建電腦的作業系統為 Microsoft Windows 10,具備強效的 CPU 與 120 GB 的硬碟,可確保儀器能靈活儲存並處理上千筆結果。高解析度 10.4 吋 LCD 觸控螢幕為簡易導引式操作的理想選擇。
若要操作螢光分析儀,請接上標準市電,然後即可開啟電源。

方便通訊
標準計算機外圍設備的 USB 與網路連接支援擴展使用、應用開發與操作員操作。

防溢保護
為了保護系統的脆弱核心,防溢箔片已經準備好了。若是發生溢出的情況,操作員可以輕鬆地更換箔片。

Accessories
軟體

Epsilon 應用軟體
Epsilon 軟體是 XRF 分析軟體平台,能與 PANalytical 的 Epsilon 1 與 Epsilon 4 系列桌上型 EDXRF 系統搭配使用。
Support
Services
Solutions to maximize the return on your investment
To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.
Support
Service for a lifetime
- Phone and remote support
- Preventive maintenance and checkups
- Flexible Customer Care Agreements
- Performance certificates
- Hardware and software upgrades
- Local and global support
Expertise
Adding value to your processes
- Sample preparation development/optimization
- Analytical methodologies
- Turnkey solutions for XRD
- Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
- Automation of lab processes
- Consultancy services
Training and education
- Training on-site or at our competence centers
- Broad range of basic and advanced courses on products, applications and software
Analytical services and calibration materials
- Expert (XRF) analyses services
- Oxides and trace analysis
- Customized calibration materials