![](https://p3.aprimocdn.net/malvernpanalytical/43168290-9a94-467d-a4a0-b0d900c83c6d/L11_Zetium_Ultimate_Edition_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Edições industriais
Soluções específicas para indústrias específicas
![](https://p3.aprimocdn.net/malvernpanalytical/43168290-9a94-467d-a4a0-b0d900c83c6d/L11_Zetium_Ultimate_Edition_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
![](https://p3.aprimocdn.net/malvernpanalytical/199fc43e-80f3-45a6-8a86-b0d900c841db/L14_Zetium_in_Automation1_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Cement edition do Zetium
![](https://p3.aprimocdn.net/malvernpanalytical/ddbfbfbc-3429-4fe6-8197-b0d900c84435/L15_Zetium_Metals-Edition_bew_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Metals edition do Zetium
![](https://p3.aprimocdn.net/malvernpanalytical/ee772707-26d6-44c1-9776-ad9e00dbb527/636378888111636462OR_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Petro edition do Zetium
![](https://p3.aprimocdn.net/malvernpanalytical/8ac307c5-74b6-45a9-aa5b-b0d900c8475c/L26_Zetium_Polymers_Edition_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Polymers edition do Zetium
![](https://p3.aprimocdn.net/malvernpanalytical/8886d026-923f-4e32-81e0-b0d900c848de/L31_Zetium_Minerals_Edition_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Minerals edition do Zetium
Visão geral
Inovação elementar
Desenvolvimento contínuo, melhoria na experiência do cliente
As inovações cientificamente adequadas e orientadas a benefícios são obtidas com a tecnologia SumXcore, uma integração de WDXRF e EDXRF - incorporada à plataforma Zetium para proporcionar o máximo em flexibilidade, desempenho e versatilidade, com o intuito de revolucionar o mundo de XRF.
![Inovação elementar](https://p3.aprimocdn.net/malvernpanalytical/9ab7bc13-8237-4046-9d9b-ada000ea6e36/637242634886646797ZZ_Original%20file.jpg?quality=60)
Inteligência elementar
O hardware analítico avançado requer software analítico avançado e expertise
Um passo quântico para o nosso renomado software SuperQ permite acesso a novas combinações de tecnologias e possibilidades analíticas. Estrelando o Virtual Analyst, que aumenta a experiência do usuário na configuração e operação do sistema.
![Inteligência elementar](https://p3.aprimocdn.net/malvernpanalytical/923d5ad0-507a-4509-8f83-ad9e00daf61e/636378879802358845ZN_Original%20file.jpg?quality=60)
Suporte elementar
Suporte transparente e confiável independentemente da localização
Do serviço à especialização, do treinamento às análises laboratoriais, o usuário terá suporte de todos os lados. Com uma grande rede mundial de engenheiros experientes conectados com o maior grupo de especialistas de aplicação, a Malvern Panalytical está sempre pronta para ajudá-lo a atender às suas exigências analíticas.
![Suporte elementar](https://p3.aprimocdn.net/malvernpanalytical/63bbe985-528f-4b12-ac39-ad9e00ebb45b/636567081056869373HY_Original%20file.png?quality=60)
Tecnologia elementar
60 anos de experiência e herança - o ponto ideal de partida
O Zetium é a próxima geração de espectrômetros WDXRF de enorme sucesso, incluindo Axios, MagiX e PW2400. Essa herança de tecnologia comprovada foi refinada e apresentada para fornecer a base da plataforma Zetium.
![Tecnologia elementar](https://p3.aprimocdn.net/malvernpanalytical/c3d9885a-f438-42e7-a575-b0d900c8367a/L05_PN9600_080_090_mod_FRKL_Original%20file.jpg?quality=60)
Características
Melhor desempenho de análise
- Aumento de potência de 1 para 2,4, 3 ou 4 kW para maior sensibilidade
- Linha de materiais de ânodo da ampola de raios X Rh, Cr, Mo e Au para desempenho de aplicações específicas
- Detector duplex para maior sensibilidade e maior faixa dinâmica para análise de metais de transição
- Detector de cintilação HiPer para aumentar a faixa dinâmica para elementos pesados (linear até 3,5 Mcps), ideal para análise de alta precisão de Nb e Mo em aços
Experiência superior do usuário
- Software simples e intuitivo com o Analista virtual
- Linha completa de módulos de configuração da aplicação e soluções de software
- Análise XRF sem padrão líder do setor com Omnian - análises de materiais desconhecidos ou quando não há padrões disponíveis
- Análises de pequenos pontos multielementos com mapeamento
- Máscaras de colimador programáveis para tamanhos de amostras entre 6 mm e 37 mm
Produtividade máxima das amostras
- Tecnologia SumXcore - tempos de medição reduzidos em até 50% com ED core
- Aumento de potência de 1 para 2,4, 3 ou 4 kW para tempos de análise mais rápidos
- Canais Hi-Per para medição simultânea de elementos leves
- Carregamento de amostras contínuo e direto que reduz significativamente a sobrecarga dos instrumentos
- Suporte de alimentador automático de amostras de alta capacidade (até 209 posições) para aplicações com alta produtividade
- A opção de leitor do código de barras do alimentador automático de amostras possibilita carregamento de amostras e entrada de dados com rapidez e sem erros
Robustez
- O dispositivo de remoção de poeira minimiza a contaminação e maximiza o tempo de atividade do equipamento
- Revestimento da janela do tubo de raio X CHI-BLUE para maior durabilidade do tubo de raio X e maior resistência à corrosão
- Identificação do tipo de amostra (sólidos e líquidos)
- Leitor de código de barras para entrada sem erros da amostra
Baixo custo de propriedade
- Economia de espaço, design compacto
- Design com câmara pneumática de pequeno volume - para ciclos rápidos de amostras em vácuo, ou baixo consumo de He para análise de líquidos
- Módulos de manutenção de fácil acesso para mais rapidez na manutenção do instrumento e menos tempo de inatividade
- A unidade de refrigeração especial remove o calor do laboratório - evitando sobrecarregar a infraestrutura de ar condicionado do laboratório
- Pacote de soluções com economia de custos
Acessórios
Padrões (materiais de referência)
Fluxos e produtos químicos
![](https://p3.aprimocdn.net/malvernpanalytical/60fa7a14-dda1-49a0-a895-ad9e00e77a6f/636437438736982238JC_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Fluxos de borato e produtos químicos
![](https://p3.aprimocdn.net/malvernpanalytical/718ecc59-9601-4a38-81f2-ad9e00e76c87/636437429871859361KE_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Monitor de fusão
![](https://p3.aprimocdn.net/malvernpanalytical/7db10bf5-f458-4575-983b-ad9e00ebc2ef/636567270153108038AK_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Oxidantes e agente sem umectação
Moldes e cadinhos
![](https://p3.aprimocdn.net/malvernpanalytical/9a0c87e5-0b68-41d6-a269-ad9e00e77eeb/636437448075556297LA_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Moldes e cadinhos
![](https://p3.aprimocdn.net/malvernpanalytical/0cb82892-43ef-43d9-9447-ad9e00e78618/636437452548431171QC_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Política de sucata de metais preciosos
Software
![](https://p3.aprimocdn.net/malvernpanalytical/d1bb5dc9-faad-45eb-955e-ad9e00eb3981/636553446661608931RJ_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Super Q
O software SuperQ é simples e torna os espectrômetros Zetium e CubiX acessíveis aos administradores e aos operadores de rotina.
![](https://p3.aprimocdn.net/malvernpanalytical/d63da356-ca38-4593-aff7-ad9e00eb435f/636553448829680388ER_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Omnian
O software Omnian permite aos usuários obter a melhor análise possível quando métodos ou padrões certificados especiais não existem.
![](https://p3.aprimocdn.net/malvernpanalytical/281952d1-5624-41d0-800d-ad9e00ebe688/636571467622989834AQ_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Segurança de dados aprimorada
![](https://p3.aprimocdn.net/malvernpanalytical/2e9962d9-d5c2-4016-8330-ad9e00ebcd7c/636567971074520258DU_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Oil-Trace
![](https://p3.aprimocdn.net/malvernpanalytical/2159b96b-b451-4456-81f0-ad9e00ebd2bc/636567998897832339BQ_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Pro-Trace
O Pro-Trace é ideal para o cálculo das intensidades líquidas na análise de elementos traço e na correção precisa de matrizes quando a matriz total é desconhecida.
![](https://p3.aprimocdn.net/malvernpanalytical/872809e3-19a7-4be2-a26f-ad9e00eb4d6e/636553450288823846JK_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Stratos
Serviços
![](https://p3.aprimocdn.net/malvernpanalytical/7c1cd4af-fba8-4914-840b-ad9e00f4592b/636626786500426904CZ_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
XRF testing services
Malvern Panalytical offers a range of analytical services, ranging from elemental, structural and morphological analysis to validation and qualification services.
![](https://p3.aprimocdn.net/malvernpanalytical/a3a516f1-cef2-4a4a-912d-ada0015c1064/637522759976832680WX_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Smart Manager
O Smart Manager é o seu guardião confiável para o gerenciamento da utilização e da integridade do instrumento, garantindo precisão, confiabilidade e eficiência incomparáveis em suas análises – pontualmente, o tempo todo.
Opções
Pacotes de aprimoramento do sistema
- Melhorias de desempenho orientadas a tarefas
- Alta produtividade de amostras - aumento da capacidade do alimentador automático de amostras e menor sobrecarga sobre o instrumento
- Proteção contra amostras empoeiradas e respingos de líquido
- Introdução de amostra isenta de erros com o leitor de código de barras
- Manuseio de tipos de amostras variáveis, incluindo análise pequenos pontos
![Pacotes de aprimoramento do sistema](https://p3.aprimocdn.net/malvernpanalytical/d5b6cb48-1813-4c06-a344-ad9e00eb128a/636549011337597124CG_Original%20file.jpg?quality=60)
SumXcore
ED core
A plataforma Zetium incorpora a tecnologia SumXcore, uma integração de WDXRF e EDXRF. Essa combinação exclusiva de possibilidades coloca o Zetium em uma classe exclusiva com relação a potência, velocidade e flexibilidade de tarefas de análise.
Benefícios combinados de WD/ED XRF
- Máximo de flexibilidade nas tarefas e desempenho aprimorado com medições simultâneas SumXcore
- Benefício dos tempos de medição reduzidos significativamente em até 50%, ou mais precisão
- Detector SDD de alta resolução, com atenuação de sinal variável, para melhor desempenho flexibilidade
- Análise elementar de Na - Am, em concentrações de ppm - 100%
- Rastreamento de elementos inesperados que possam afetar a análise de elemento de processo sem aumentar o tempo de medição
- Aprimoramento do programa de QA/QC e aumento da confiança na qualidade com dois resultados independentes para todas as medições
![SumXcore](https://p3.aprimocdn.net/malvernpanalytical/5b4deb7f-419b-49c9-ad9a-ad9e00eb228e/636552612515215577UK_Original%20file.jpg?quality=60)
SuperQ 6 com Analista Virtual
O Analista Virtual obtém as informações de várias fontes, como composições padrão, medições reais e objetivos de dados do usuário, para calcular a resposta do sistema, configurá-la e concluir o método.
- Acesso ao poder da plataforma Zetium
- Simples e intuitivo com fluxo orientado a tarefas
- Ajustes de correção de matriz avançada para aumentar a precisão dos dados a partir de metais até polímeros
- Analista Virtual - incorporação de décadas de conhecimento especializado.
![SuperQ 6 com Analista Virtual](https://p3.aprimocdn.net/malvernpanalytical/91eb85a4-9462-4601-a1d1-ad9e00eb2e1b/636552624559792469JI_Original%20file.jpg?quality=60)
Análise de pequenos pontos com mapeamento
A análise de pequenos pontos com mapeamento de distribuição dos elementos é uma ferramenta ideal para a pesquisa de materiais e a solução de problemas do processo de produção. Não mais restrita a instalações de pesquisa, essa técnica agora está disponível em qualquer lugar que você precisar.
- Ideal para pesquisa de materiais e solução de problemas do processo de produção
- Tempos de análise prática
- Trajeto óptico bem acoplado para alta sensibilidade
- Usa ED core para análise multielementos simultânea por ponto
- Tamanho de ponto de 500 μm (FWHM), 100 μm de tamanho da etapa
- Análise sem padrões Omnian quantitativa e qualitativa
- Preparação de amostra simples
![Análise de pequenos pontos com mapeamento](https://p3.aprimocdn.net/malvernpanalytical/88c0af2a-c865-4fc2-b5bb-ad9e00ebb9f0/636567082707508999AF_Original%20file.jpg?quality=60)