![](https://p3.aprimocdn.net/malvernpanalytical/43168290-9a94-467d-a4a0-b0d900c83c6d/L11_Zetium_Ultimate_Edition_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Ediciones de la industria
Soluciones personalizadas para industrias específicas
![](https://p3.aprimocdn.net/malvernpanalytical/43168290-9a94-467d-a4a0-b0d900c83c6d/L11_Zetium_Ultimate_Edition_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
![](https://p3.aprimocdn.net/malvernpanalytical/199fc43e-80f3-45a6-8a86-b0d900c841db/L14_Zetium_in_Automation1_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
La edición Cement de Zetium
![](https://p3.aprimocdn.net/malvernpanalytical/ddbfbfbc-3429-4fe6-8197-b0d900c84435/L15_Zetium_Metals-Edition_bew_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
La edición Metals de Zetium
![](https://p3.aprimocdn.net/malvernpanalytical/ee772707-26d6-44c1-9776-ad9e00dbb527/636378888111636462OR_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
La edición Petro de Zetium
![](https://p3.aprimocdn.net/malvernpanalytical/8ac307c5-74b6-45a9-aa5b-b0d900c8475c/L26_Zetium_Polymers_Edition_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
La edición Polymers de Zetium
![](https://p3.aprimocdn.net/malvernpanalytical/8886d026-923f-4e32-81e0-b0d900c848de/L31_Zetium_Minerals_Edition_B_mod_FRKL_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
La edición Minerals de Zetium
Información general
Innovación elemental
Desarrollo continuo, mejor experiencia del cliente
Las innovaciones con base científica e impulsadas por los beneficios obtenidas con la tecnología SumXcore (una integración de WDXRF y EDXRF), incorporada en la plataforma Zetium, proporcionan la máxima flexibilidad, rendimiento y versatilidad, y están en camino a revolucionar el mundo de XRF.
![Innovación elemental](https://p3.aprimocdn.net/malvernpanalytical/9ab7bc13-8237-4046-9d9b-ada000ea6e36/637242634886646797ZZ_Original%20file.jpg?quality=60)
Inteligencia elemental
El hardware de analítica avanzada requiere experiencia y un software de analítica avanzada
Un paso significativo para nuestro reconocido software SuperQ da acceso a combinaciones y posibilidades analíticas de la nueva tecnología. Junto con Virtual Analyst, mejora la experiencia del usuario en la configuración y la operación del sistema.
![Inteligencia elemental](https://p3.aprimocdn.net/malvernpanalytical/923d5ad0-507a-4509-8f83-ad9e00daf61e/636378879802358845ZN_Original%20file.jpg?quality=60)
Asistencia elemental
Asistencia transparente y confiable sin importar la ubicación
Desde servicio hasta asesoría, desde capacitación hasta análisis de laboratorio, el usuario recibe asistencia desde todos los ángulos. Con una red mundial de ingenieros expertos, junto con el consorcio más grande de la industria de científicos de aplicaciones, Malvern Panalytical está siempre disponible para ayudarlo a satisfacer sus necesidades analíticas.
![Asistencia elemental](https://p3.aprimocdn.net/malvernpanalytical/63bbe985-528f-4b12-ac39-ad9e00ebb45b/636567081056869373HY_Original%20file.png?quality=60)
Tecnología elemental
60 años de experiencia y legado: el punto de partida ideal
Zetium es el futuro en una generación de espectrómetros de WDXRF de notable éxito, como Axios, MagiX y PW2400. Este legado de tecnología probada se mejoró y recibió avances para proporcionar la base a la plataforma Zetium.
![Tecnología elemental](https://p3.aprimocdn.net/malvernpanalytical/c3d9885a-f438-42e7-a575-b0d900c8367a/L05_PN9600_080_090_mod_FRKL_Original%20file.jpg?quality=60)
Características
Rendimiento analítico mejorado
- Optimización de potencia de 1 a 2,4, 3 o 4 kW para una sensibilidad mejorada
- Gama de materiales anódicos Rh, Cr, Mo y Au del tubo de rayos X para un rendimiento específico de aplicaciones
- Detector doble para sensibilidad mejorada y un rango dinámico más amplio para el análisis de metales de transición
- Detector de centelleo de alto rendimiento para mayor rango dinámico de elementos pesados (lineal de hasta 3,5 Mcps), ideal para análisis de alta precisión de niobio y molibdeno en aceros
Experiencia de usuario superior
- Software sencillo e intuitivo con Virtual Analyst
- Conjunto completo de módulos de configuración de aplicaciones y soluciones de software
- Análisis de XRF sin estándares líder en la industria con Omnian: análisis de elementos desconocidos o cuando las normas no están disponibles
- Análisis de puntos pequeños de diversos elementos con clasificación
- Máscaras del colimador programables para tamaños de muestra de entre 6 mm y 37 mm.
Máximo rendimiento de la muestra
- Tecnología SumXcore: reducción de los tiempos de medición de hasta el 50 %, con un programa ED
- Optimización de potencia de 1 a 2,4, 3 o 4 kW para menores tiempos de análisis
- Canales de alto rendimiento para medición simultánea de elementos livianos
- La carga de muestras constante y directa reduce significativamente la sobrecarga del instrumento
- Alojamiento del cambiador de muestra de alta capacidad (hasta 209 posiciones) para aplicaciones de alto rendimiento
- La opción de lector de código de barras del cambiador de muestra permite una carga de muestras y una entrada de datos rápidas y sin errores.
Solidez
- El dispositivo de eliminación de polvo minimiza la contaminación y maximiza el tiempo de funcionamiento del instrumento
- Revestimiento de la ventana del tubo de rayos X CHI-BLUE para mayor durabilidad del tubo de rayos X y resistencia a la corrosión
- Identificación del tipo de muestra (sólidos y líquidos)
- Lector de código de barras para una entrada de muestras sin errores
Bajo costo de propiedad
- Diseño compacto
- Diseño de bloqueo de aire de pequeños volúmenes para ciclos rápidos de las muestras en el vacío o bajo consumo de helio para análisis de líquidos
- Los módulos de servicio de fácil acceso permiten un mantenimiento más rápido del instrumento y un tiempo de inactividad mínimo
- El enfriador especializado elimina el calor del laboratorio, lo que evita sobrecargar la infraestructura de aire acondicionado del laboratorio
- Soluciones en paquetes económicas
Accesorios
Estándares (materiales de referencia)
Fundentes y productos químicos
![](https://p3.aprimocdn.net/malvernpanalytical/60fa7a14-dda1-49a0-a895-ad9e00e77a6f/636437438736982238JC_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Fundentes de borato y productos químicos
![](https://p3.aprimocdn.net/malvernpanalytical/718ecc59-9601-4a38-81f2-ad9e00e76c87/636437429871859361KE_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Control de fusiones
![](https://p3.aprimocdn.net/malvernpanalytical/7db10bf5-f458-4575-983b-ad9e00ebc2ef/636567270153108038AK_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Oxidantes y agente no humectante
Moldes y crisoles
![](https://p3.aprimocdn.net/malvernpanalytical/9a0c87e5-0b68-41d6-a269-ad9e00e77eeb/636437448075556297LA_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Moldes y crisoles
![](https://p3.aprimocdn.net/malvernpanalytical/0cb82892-43ef-43d9-9447-ad9e00e78618/636437452548431171QC_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Política de chatarra de metales preciosos
Software
![](https://p3.aprimocdn.net/malvernpanalytical/d1bb5dc9-faad-45eb-955e-ad9e00eb3981/636553446661608931RJ_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
SuperQ
El software SuperQ es sencillo y pone los espectrómetros Zetium y CubiX a disposición de administradores y operadores frecuentes.
![](https://p3.aprimocdn.net/malvernpanalytical/d63da356-ca38-4593-aff7-ad9e00eb435f/636553448829680388ER_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Omnian
El software Omnian permite a los usuarios obtener el mejor análisis posible cuando no hay disponibles métodos especializados o normas certificadas.
![](https://p3.aprimocdn.net/malvernpanalytical/281952d1-5624-41d0-800d-ad9e00ebe688/636571467622989834AQ_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Seguridad de datos mejorada
![](https://p3.aprimocdn.net/malvernpanalytical/2e9962d9-d5c2-4016-8330-ad9e00ebcd7c/636567971074520258DU_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Oil-Trace
![](https://p3.aprimocdn.net/malvernpanalytical/2159b96b-b451-4456-81f0-ad9e00ebd2bc/636567998897832339BQ_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Pro-Trace
Pro-Trace es ideal para calcular intensidades netas en análisis de oligoelementos y corrección de matriz precisa cuando se desconoce el total de la matriz.
![](https://p3.aprimocdn.net/malvernpanalytical/872809e3-19a7-4be2-a26f-ad9e00eb4d6e/636553450288823846JK_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Stratos
Servicios
![](https://p3.aprimocdn.net/malvernpanalytical/7c1cd4af-fba8-4914-840b-ad9e00f4592b/636626786500426904CZ_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
XRF testing services
Malvern Panalytical offers a range of analytical services, ranging from elemental, structural and morphological analysis to validation and qualification services.
![](https://p3.aprimocdn.net/malvernpanalytical/a3a516f1-cef2-4a4a-912d-ada0015c1064/637522759976832680WX_Original%20file.jpg?quality=60&width=532&crop=2:1,smart)
Smart Manager
Smart Manager es su guardián de confianza para la gestión del estado y la utilización de los instrumentos, lo que garantiza una precisión, confiabilidad y eficiencia inigualables en sus análisis, a tiempo y en todo momento.
Opciones
Paquetes de mejora del sistema
- Mejoras de rendimiento orientadas a las tareas
- Alto rendimiento de la muestra: mayor capacidad del cambiador de muestras y menor sobrecarga del instrumento
- Protección contra muestras con polvo y derrames de líquidos
- Introducción de muestras sin errores con lector de código de barras
- Manejo de tipo de muestra variable, que incluye análisis de puntos pequeños
![Paquetes de mejora del sistema](https://p3.aprimocdn.net/malvernpanalytical/d5b6cb48-1813-4c06-a344-ad9e00eb128a/636549011337597124CG_Original%20file.jpg?quality=60)
SumXcore
Programa ED
La plataforma Zetium incorpora la tecnología SumXcore, una integración de WDXRF y EDXRF. Esta combinación única de posibilidades pone esta tecnología en una clase propia con respecto a la capacidad analítica, la velocidad y la flexibilidad de tareas.
Beneficios de WDXRF y EDXRF combinados
- Máxima flexibilidad de tareas y rendimiento mejorado con mediciones simultáneas de SumXcore
- Beneficio mediante tiempo de medición considerablemente reducido en hasta un 50 % o mediante mejor precisión
- Detector SDD de alta resolución, con atenuación de señal variable, para obtener una flexibilidad de rendimiento óptima
- Análisis elemental desde sodio hasta americio, en concentraciones de ppm a un 100 %
- Dele seguimiento a elementos inesperados que pueden afectar el análisis de elementos del proceso sin aumentar el tiempo de medición
- Mejore su programa de QA/QC y aumente la confianza en la calidad con dos resultados independientes para cada medición
![SumXcore](https://p3.aprimocdn.net/malvernpanalytical/5b4deb7f-419b-49c9-ad9a-ad9e00eb228e/636552612515215577UK_Original%20file.jpg?quality=60)
SuperQ 6 con Virtual Analyst
Virtual Analyst obtiene información de muchas fuentes, tales como composiciones estándares, mediciones reales y objetivos de datos de usuario, para calcular la respuesta del sistema, configurarlo y completar el método.
- Acceso a la potencia de la plataforma Zetium
- Sencilla e intuitiva con flujo orientado a las tareas
- Perfeccionamiento avanzado de corrección de matriz para mayor precisión de los datos, desde metales hasta polímeros
- Virtual Analyst: materialización de décadas de conocimiento especializado.
![SuperQ 6 con Virtual Analyst](https://p3.aprimocdn.net/malvernpanalytical/91eb85a4-9462-4601-a1d1-ad9e00eb2e1b/636552624559792469JI_Original%20file.jpg?quality=60)
Análisis de puntos pequeños con clasificación
El análisis de puntos pequeños con clasificación de distribución de elementos es una herramienta ideal para la investigación de materiales y la solución de problemas del proceso de producción. Ya no limitada a instalaciones de investigación, esta técnica ahora está disponible siempre que lo necesite.
- Ideal para la investigación de materiales y la solución de problemas del proceso de producción
- Tiempos de análisis prácticos
- Trayectoria óptica de acoplamiento compacto de alta sensibilidad
- Utiliza el programa ED para un análisis rápido y simultáneo de diversos elementos por punto
- 500 µm de tamaño de punto (FWHM), 100 µm de tamaño de paso
- Análisis cuantitativos, cualitativos y sin estándares de Omnian
- Preparación simple de la muestra
![Análisis de puntos pequeños con clasificación](https://p3.aprimocdn.net/malvernpanalytical/88c0af2a-c865-4fc2-b5bb-ad9e00ebb9f0/636567082707508999AF_Original%20file.jpg?quality=60)