全新的 Zetasizer Advance – 能適用於各種應用的 DLS 技術 – 快來瞧瞧全新的 Zetasizer 系列吧!. Find out more

Find out more

Zetasizer Ultra

Zetasizer Ultra 是用于测量颗粒与分子大小、颗粒电荷和颗粒浓度的系统,在结合了 Zetasizer Pro 和 Lab 所有特性和优点的基础上,增加了多角度动态光散射技术(MADLS®),是 Zetasizer Advance 系列中最智能和灵活的仪器。 

这一旗舰型仪器充分利用了 ZS Xplorer 软件的易用性、高分析速度和数据可靠性等优势,运用多角度动态光散射技术 (MADLS®) ,提供与角度无关的高分辨率粒度测量,并且能够测量颗粒浓度*,帮助您更深入地了解样品。

*仅限 Zetasizer Ultra 红标版本 (Red Label)

下載型錄
联系应用支持

使用者手冊

軟體下載

24 September 2024

4.0.0

ZS Xplorer 4.0.0 is the first version to support the new Zetasizer Sample Assistant automated particle size and Zeta potential sample changer.  Small updates to Smart Manager components are also included.


Please Note: OmniTrust (regulated environment) users will not be able to access Sample Assistant as the feature does not currently support OmniTrust. 


See SUN for full details.

 

4.0.0

08 December 2023

3.31

Maintenance release, updates to key services and addition of Titration summary data logs.


See SUN for full details.

 

3.31

02 August 2023

3.30

ZS Xplorer version 3.3 extends OmniTrust support to the Studies features of the main application. Previously OmniTrust users were prevented from accessing Studies to prevent un-audited events. From 3.3 OmniTrust users can now access Studies for Molecular Weight and associated parameters with permissions and auditing of events within the Studies features.  


Note that Studies by their nature are intended for advanced users and to be flexible in their analysis. Users not requiring Studies features can still prevent access to these features using permissions in OmniAccess.


Version 3.3 also addresses a few minor bug fixes.


See SUN for full details.

 

3.30

02 May 2023

3.22

ZS Xplorer 3.2.2 has the following updates: 

 

Software re-branded to Malvern Panalytical brand

Minor bug fixes - one of which may have prevented instrument connection

Bug fix for OmniTrust users that meant editing of records was possible, even when user permission for this action was disabled (recommended update for OmniTrust users currently on ZS Xplorer 3.2.1.)

Updated Toluene calibration routine to prevent incorrect reporting of issues with calibration.


See SUN for full details.

3.22

19 December 2022

3.21

ZS Xplorer 3.2.1 adds Smart Instrument enrollment - the first step in bringing Zetasizer into Malvern Panalytical's Smart Manager services.

Several installer improvements have been made to reduce ZS Xplorer requirements around .NET and WebView2 components.

We have also added ability to edit peak thresholds for size measurements and refinements on CSV exporting from parameter tables.


See SUN for full details.

3.21

04 October 2022

3.20

ZS Xplorer version 3.2.0 adds upper and lower display range configuration for Size/MADLS & Particle Concentration measurements.

Introduces Data Quality Advice for MADLS & Particle Concentration measurements.  

Adds further Trend analysis improvements and bug fixes.

Extends Japanese and Chinese localization to Studies and Data Quality Advice.

Adds speed and robustness improvements to Scattering standard measurements.

Other improvements and bug fixes.  

See SUN for full details.

3.20

11 July 2022

3.10

ZS Xplorer version 3.1.0 extends studies and concentration trend measurements to support the Zetasizer Advance Lab models and also adds the capability to perform concentration trends in either back or side scatter on Zetasizer Advance Ultra models.   Concentration trends also now supports setting of measurement temperature and adds display of R2 value to tables and graphs.

Exporting of data to CSV file from graphs and tables in Concentration trends and from Parameter and Statistic tables in Analyze views has been introduced.

Data quality advice for Zeta potential measurements has been further refined to provide users with better diagnosis of sample/measurement issues. 

Exporting a study now provides an option to include the results data for transfer of the complete study between data repositories.

Various bug fixes, see software update notification for details.

3.10

18 May 2022

3.00

ZS Xplorer version 3.0.0 introduces studies and concentration trend measurements for the determination of molecular weight by static light scattering and kD by dynamic light scattering. Note: This first release does not support Zetasizer Lab or OmniTrust users. Auto averaging for Zeta, MADLS and Particle concentration has also been added along with other quality of life features and bug fixes. See SUN for details.

3.00

01 March 2022

2.31

ZS Xplorer version 2.3.1 introduces post-analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have

 

been added, as well as a count rate meter and

 

localization for Chinese (Simplified) and Japanese language support.

Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.1.

2.31

17 January 2022

2.30

ZS Xplorer version 2.3.0 introduces post analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have also been added, as well as a count rate meter.


Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.0.

details.

2.30

14 October 2021

2.20

  • Maintenance release see Software Update Notification for details.
2.20

08 July 2021

2.10

  • ZS Xplorer 2.1 offers improvements to OmniTrust regulated environment users by providing improved control of methods and provision of a method audit trail. This version also provides improvements by provision of major size distribution percentiles and automatic size averaging function. A critical bug that could  affect zeta potential data for very low scattering samples has also been fixed. See the Software Update Notification for more details.

2.10

25 February 2021

2.01

  • Bug fix: Changing sample details on locked methods
    • Fixed a bug around method permissions for OmniTrust regulated environment users that prevented editing of method sample details.
2.01

20 July 2023

1.60

OmniAccess   

  • Flexible/configurable roles in Empyrean and Aeris (now aligns with Zetasizer) 
  • Summary of roles/permissions 
  • Default roles for instrument applications 
  • Support for complex domains 
  • Wizard for initial set up and massively improved UI to improve configuration/set up 

OmniTrail  

  • Record Audit trail events viewable in OmniTrail. 
  • Show/compare authorization files 

More information can be found in the Release and Installation Notes.

1.60

16 December 2021

1.40

OmniAccess   

  • Flexible/configurable roles in Empyrean and Aeris (now aligns with Zetasizer) 
  • Summary of roles/permissions 
  • Default roles for instrument applications 
  • Support for complex domains 
  • Wizard for initial set up and massively improved UI to improve configuration/set up 

OmniTrail  

  • Record Audit trail events viewable in OmniTrail. 
  • Show/compare authorization files 

More information can be found in the Release and Installation Notes.

1.40

配件

Zetasizer Ultra 附件

Zetasizer Sample Assistant

進行自動化測試,為科學家提供所需知識

Sample Assistant 是適用於所有 Zetasizer Advance 系統的配件,能大幅提升系統使用率。該配件可減輕操作人員的負擔,讓他們不必再手動更換樣品。 

結果如何?Zetasizer Advance 的資料品質與靈活度將一如既往地優異,但效率更上一層樓。

MPT-3 自动电位滴定仪

让您的PH滴定自动化

MPT-3是Zetasizer Advance 系列的一款性价比高的配件,用于自动测定Zeta电位和/或尺寸与pH的比值,帮助您了解材料随pH值的变化规律。 

随着pH值的变化,材料的zeta电位和粒度对于理解这些变化至关重要:

  • 材料的稳定性
  • 团聚
  • 絮凝
  • 零净电荷点(等电点)
  • 储存条件

SV-10 粘度计

快速、简单、准确的粘度测量。

SV-10能够在一个非常简单和快速的系统中测量粘度,达到动态光散射所需的精度,以将扩散系数转化为粒度,将电泳迁移率转化为zeta电位。

样品池选件

Disposable folded capillary cell (DTS1070)

Eliminate sample cross contamination between zeta potential measurements using a completely disposable cell.

The zeta potential of colloids and molecules is extremely sensitive to contamination from components of a previous sample used in a measurement cell. The use of a disposable cell completely eliminates this potential contamination issue.

The folded capillary cell provides the benefits of the accuracy of measurement of a capillary cell with the ease of use of a disposable cell.

Although, disposable, including the electrodes, for low conductivity samples each cell can be used for hundreds of measurements if required.

The cell can be used with the autotitrator, where multiple measurements are routinely done over a wide pH range.

通用“插入式”样品池套件

可重复使用的耐溶剂样品池。

插入式样品池用于在水性和非水性分散剂中测量样品的zeta电位,并且可清洗和重复使用。 它可以使用标准聚苯乙烯或玻璃试管进行批量测量。

高浓度zeta电位样品池套件

测量zeta电位时几乎不用进行稀释,省时省力。

利用高浓度样品池Zetasizer Advance系统可以在少量或不稀释的条件下测量样品的zeta电位。

该样品池具有流动模式,可使用MPT- 3自动滴定仪进行流动控制,用于截流状态下粒度和zeta电位测量,以及批量测量。

Low-volume disposable sizing cell kit (ZSU1002)

Our low volume disposable sizing cell (ZSU1002) design is unique in offering easy-fill, ultra-low volume size measurement in as little as 3 μL. 

  • Measure larger particles (up to 10 μm) with greater accuracy thanks to the inherent physical qualities of the capillary sizing cell
  • The cell also eliminates the errors associated with multiple scattering, allowing samples to be measured over a wider dynamic concentration range than would normally be possible at side scatter (90°)
  • The use of ZSU1002 is supported on Zetasizer Lab and Zetasizer Ultra models
12mm 方形玻璃样品池 (PCS8501)

12mm 方形玻璃样品池 (PCS8501)

进行批量测量的玻璃样品池。

  • 用于粒度及分子量测量。
  • 兼容水性及非水性溶液与分散剂。
12mm玻璃样品池 (PCS1115)

12mm玻璃样品池 (PCS1115)

与插入式样品池配合使用的玻璃样品池

  • 使用插入式样品池测量粒度及Zeta电位。
  • 兼容水性及非水性溶液与分散剂。
低容量石英样品池(ZEN2112)

低容量石英样品池(ZEN2112)

粒度及分子量测量用低容积石英样品池。

这种石英样品池可容纳 12 μL 到 45 μL 样品,适用于粒度测量。 它同时兼容水性和非水性溶剂和分散剂。

12mm 方形聚苯乙烯样品池(DTS0012)

12mm 方形聚苯乙烯样品池(DTS0012)

可抛弃型聚苯乙烯样品池。

  • 100个可抛弃型样品池,搭配100个塞子,避免交叉污染。
  • 使用水性分散剂进行粒度测量。
  • 和插入式样品池兼容检测Zeta电位。
可抛弃型耐溶剂微量样品池(ZEN0040)

可抛弃型耐溶剂微量样品池(ZEN0040)

可抛弃型塑料微量样品池,仅用于在173° (NIBS) 光学条件下进行粒度测量。

  • 100 x 40 µL样品池,配100个盖,避免交叉污染。
  • 兼容水性样品及一系列其它溶剂:丙酮、 苯甲醛、丁酮、二恶烷、DMF、乙酸乙酯、异丙醇,以及多种酸与碱。

活動和培訓

All Events

Class & Workshop | English |

In-Person Zetasizer Advance Training - UK

產品:
Zetasizer Advance 系列, Zetasizer Lab, Zetasizer Lab (Blue), Zetasizer Pro, Zetasizer Pro (Blue), Zetasizer Ultra, Zetasizer Ultra (Blue), Zetasizer Lab, Zetasizer Pro, Zetasizer Ultra
技術類型:
光散射, 多角度動態光散射 (MADLS)
產業應用:
學術界, 先進製造, 航太, 農業, 汽車, 建築材料, 化學品, 化學品/塗層, 半導體/電子, 能源/電池, 環境, 政府/機構, 食品與飲料分析, 金屬, 礦物質, 礦業, 油、燃料和化學品, 個人護理產品, 聚合物, 發電, 服務實驗室/集成商, 學院
In-Person Zetasizer Advance Training - UK

Class & Workshop | English |

Virtual Zetasizer Advance Training - EMEA

產品:
Zetasizer Advance 系列, Zetasizer Lab, Zetasizer Lab (Blue), Zetasizer Pro, Zetasizer Pro (Blue), Zetasizer Ultra, Zetasizer Ultra (Blue), Zetasizer Lab, Zetasizer Pro, Zetasizer Ultra
技術類型:
光散射, 多角度動態光散射 (MADLS)
產業應用:
學術界, 先進製造, 航太, 農業, 汽車, 建築材料, 化學品, 化學品/塗層, 半導體/電子, 能源/電池, 環境, 政府/機構, 食品與飲料分析, 金屬, 礦物質, 礦業, 油、燃料和化學品, 個人護理產品, 聚合物, 發電, 服務實驗室/集成商, 學院
Virtual Zetasizer Advance Training - EMEA

Class & Workshop | English |

In-Person Zetasizer Advance Training - UK

產品:
Zetasizer Advance 系列, Zetasizer Lab, Zetasizer Lab (Blue), Zetasizer Pro, Zetasizer Pro (Blue), Zetasizer Ultra, Zetasizer Ultra (Blue), Zetasizer Lab, Zetasizer Pro, Zetasizer Ultra
技術類型:
光散射, 多角度動態光散射 (MADLS)
產業應用:
學術界, 先進製造, 航太, 農業, 汽車, 建築材料, 化學品, 化學品/塗層, 半導體/電子, 能源/電池, 環境, 政府/機構, 食品與飲料分析, 金屬, 礦物質, 礦業, 油、燃料和化學品, 個人護理產品, 聚合物, 發電, 服務實驗室/集成商, 學院
In-Person Zetasizer Advance Training - UK

Class & Workshop | English |

Virtual Zetasizer Advance Training - EMEA

產品:
Zetasizer Advance 系列, Zetasizer Lab, Zetasizer Lab (Blue), Zetasizer Pro, Zetasizer Pro (Blue), Zetasizer Ultra, Zetasizer Ultra (Blue), Zetasizer Lab, Zetasizer Pro, Zetasizer Ultra
技術類型:
光散射, 多角度動態光散射 (MADLS)
產業應用:
學術界, 先進製造, 航太, 農業, 汽車, 建築材料, 化學品, 化學品/塗層, 半導體/電子, 能源/電池, 環境, 政府/機構, 食品與飲料分析, 金屬, 礦物質, 礦業, 油、燃料和化學品, 個人護理產品, 聚合物, 發電, 服務實驗室/集成商, 學院
Virtual Zetasizer Advance Training - EMEA

支持合同的选项

透過 Malvern Panalytical 的服務計畫保護您的投資並確保機臺隨時都具有最佳效能。

我們瞭解當您購買 Malvern Panalytical 的產品時,這只是雙方合作關係的第一階段,其關係將持續到遺棄的整個使用壽命。因此根據您的需求, Malvern Panalytical 將為您量身打造後續的設備維護方案

服務資訊

  • 電話或 Email 支援
  • 我們將會有專員負責接聽您的來電並確保您的需求得到回應

訓練課程

  • 使用者訓練課程

軟體下載

Malvern Panalytical的服務選項-請選擇適合您的計畫:

Malvern Panalytical Platinum

對實驗室來說,最大化遺棄的正常運行時間對其日常效能至關重要。若是不幸發生,我們最高等級的回應與「全權負責」的價格計畫將會處理那些意外的維修費用。

Malvern Panalytical Gold

藉由維持儀器的效率以提高實驗室的生產力。仍然具備優先回應待遇,再配合專業技術與軟體的支援,我們將維持您的儀器效能能夠正常運作。

Malvern Panalytical Bronze

對於期望優化儀器效能、定期預防性維護至關重要。

Platinum PlanGold PlanBronze Visit
年度 PM/PV 測試
電話/e-mail 支援
優先回應
緊急故障叫修*
包含零件
軟體和技術支援
IQ/OQ (製藥業)***

*包含維修和差旅費用 ***需支付額外費用

联系应用支持