Zetasizer Advance Series User Guide (English)
版本号: MAN0592-15-EN
全新的 Zetasizer Advance – 能適用於各種應用的 DLS 技術 – 快來瞧瞧全新的 Zetasizer 系列吧!. Find out more
Find out more版本号: MAN0592-15-EN
版本号: MAN0593-10-EN
版本号: MAN0604-05-EN
版本号: MAN0593-05-EN
ZS Xplorer 4.1.0 release further extends Zetasizer Sample Assistant integration with additional features and quality of life improvements.
ZS Xplorer 4.1.0 introduces support for sample storage thermoblocks.
General improvements to Sample Assistant robustness and ability to pause running sessions added.
ZS Xplorer 4.0.0 is the first version to support the new Zetasizer Sample Assistant automated particle size and Zeta potential sample changer. Small updates to Smart Manager components are also included.
Please Note: OmniTrust (regulated environment) users will not be able to access Sample Assistant as the feature does not currently support OmniTrust.
See SUN for full details.
Maintenance release, updates to key services and addition of Titration summary data logs.
See SUN for full details.
ZS Xplorer version 3.3 extends OmniTrust support to the Studies features of the main application. Previously OmniTrust users were prevented from accessing Studies to prevent un-audited events. From 3.3 OmniTrust users can now access Studies for Molecular Weight and associated parameters with permissions and auditing of events within the Studies features.
Note that Studies by their nature are intended for advanced users and to be flexible in their analysis. Users not requiring Studies features can still prevent access to these features using permissions in OmniAccess.
Version 3.3 also addresses a few minor bug fixes.
See SUN for full details.
ZS Xplorer 3.2.2 has the following updates:
Software re-branded to Malvern Panalytical brand
Minor bug fixes - one of which may have prevented instrument connection
Bug fix for OmniTrust users that meant editing of records was possible, even when user permission for this action was disabled (recommended update for OmniTrust users currently on ZS Xplorer 3.2.1.)
Updated Toluene calibration routine to prevent incorrect reporting of issues with calibration.
See SUN for full details.
ZS Xplorer 3.2.1 adds Smart Instrument enrollment - the first step in bringing Zetasizer into Malvern Panalytical's Smart Manager services.
Several installer improvements have been made to reduce ZS Xplorer requirements around .NET and WebView2 components.
We have also added ability to edit peak thresholds for size measurements and refinements on CSV exporting from parameter tables.
See SUN for full details.
ZS Xplorer version 3.2.0 adds upper and lower display range configuration for Size/MADLS & Particle Concentration measurements.
Introduces Data Quality Advice for MADLS & Particle Concentration measurements.
Adds further Trend analysis improvements and bug fixes.
Extends Japanese and Chinese localization to Studies and Data Quality Advice.
Adds speed and robustness improvements to Scattering standard measurements.
Other improvements and bug fixes.
See SUN for full details.
ZS Xplorer version 3.1.0 extends studies and concentration trend measurements to support the Zetasizer Advance Lab models and also adds the capability to perform concentration trends in either back or side scatter on Zetasizer Advance Ultra models. Concentration trends also now supports setting of measurement temperature and adds display of R2 value to tables and graphs.
Exporting of data to CSV file from graphs and tables in Concentration trends and from Parameter and Statistic tables in Analyze views has been introduced.
Data quality advice for Zeta potential measurements has been further refined to provide users with better diagnosis of sample/measurement issues.
Exporting a study now provides an option to include the results data for transfer of the complete study between data repositories.
Various bug fixes, see software update notification for details.
ZS Xplorer version 3.0.0 introduces studies and concentration trend measurements for the determination of molecular weight by static light scattering and kD by dynamic light scattering. Note: This first release does not support Zetasizer Lab or OmniTrust users. Auto averaging for Zeta, MADLS and Particle concentration has also been added along with other quality of life features and bug fixes. See SUN for details.
ZS Xplorer version 2.3.1 introduces post-analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have
been added, as well as a count rate meter and
localization for Chinese (Simplified) and Japanese language support.
Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.1.
ZS Xplorer version 2.3.0 introduces post analysis averaging for Zeta, Particle Concentration and MADLS size measurements. Zeta mobility parameters and graphs have also been added, as well as a count rate meter.
Important: This version supports OmniTrust 1.4.0; OmniTrust users should upgrade their installation to 1.4 if upgrading to ZS Xplorer 2.3.0.
details.
OmniTrust software update v1.7a
OmniAccess
OmniTrail
More information can be found in the Release and Installation Notes.
OmniAccess
OmniTrail
More information can be found in the Release and Installation Notes.
Sample Assistant 是適用於所有 Zetasizer Advance 系統的配件,能大幅提升系統使用率。該配件可減輕操作人員的負擔,讓他們不必再手動更換樣品。
結果如何?Zetasizer Advance 的資料品質與靈活度將一如既往地優異,但效率更上一層樓。
MPT-3是Zetasizer Advance 系列的一款性价比高的配件,用于自动测定Zeta电位和/或尺寸与pH的比值,帮助您了解材料随pH值的变化规律。
随着pH值的变化,材料的zeta电位和粒度对于理解这些变化至关重要:
SV-10能够在一个非常简单和快速的系统中测量粘度,达到动态光散射所需的精度,以将扩散系数转化为粒度,将电泳迁移率转化为zeta电位。
The zeta potential of colloids and molecules is extremely sensitive to contamination from components of a previous sample used in a measurement cell. The use of a disposable cell completely eliminates this potential contamination issue.
The folded capillary cell provides the benefits of the accuracy of measurement of a capillary cell with the ease of use of a disposable cell.
Although, disposable, including the electrodes, for low conductivity samples each cell can be used for hundreds of measurements if required.
The cell can be used with the autotitrator, where multiple measurements are routinely done over a wide pH range.
Our low volume disposable sizing cell (ZSU1002) design is unique in offering easy-fill, ultra-low volume size measurement in as little as 3 μL.
利用高浓度样品池Zetasizer Advance系统可以在少量或不稀释的条件下测量样品的zeta电位。
该样品池具有流动模式,可使用MPT- 3自动滴定仪进行流动控制,用于截流状态下粒度和zeta电位测量,以及批量测量。
利用马尔文帕纳科服务计划保护您的投资,并确保仪器发挥出色的性能。
当您购买了马尔文帕纳科产品,我们明白,这仅是建立工作关系的第一步,而这种关系将伴随仪器的整个使用寿命。 根据您的需要,为您的业务提供支持。
适用于仪器需要正常长时间运行且保持高性能的实验室。 一旦不幸发生事故,我们的最高级别响应以及“全包式”定价计划将涵盖这些意外维修的费用。
保持仪器效率,以提高实验室的生产率。 仍然能够得到优先响应,加上专家级的技术和软件支持,使您的仪器保持高性能。
适用于需要优化仪器性能的实验室,定期预防性维护是其重中之重。
白金计划 | 黄金计划 | 青铜计划 | |
---|---|---|---|
年度 PM/PV 测试 |
是
|
是
|
否
|
电话/邮件支持 |
是
|
是
|
否
|
优先响应 |
是
|
是
|
否
|
紧急停机上门服务* |
是
|
是
|
否
|
包含零件 |
是
|
否
|
否
|
在线学习** |
是
|
是
|
否
|
技术和软件支持 |
是
|
是
|
是
|
IQ/OQ(制药)*** |
是
|
是
|
是
|
*包含人工和差旅费用 ** 白金级每个合同期包含 2 处地点,黄金级每个合同期包含 1 处地点 ***需另外收费