ASD HandHeld 2 Pro: VNIR Hand-held Spectroradiometer
Discontinued for sale
The ASD FieldSpec HandHeld 2 Pro hand-held spectroradiometer offers greater sensitivity over the standard ASD HandHeld 2 spectroradiometer model, aiding spectral measurements for applications with low reflectance characteristics such as water surfaces. Wherever there is a need for enhanced sensitivity, faster collection rates, high signal to noise performance, the ASD HandHeld 2 Pro is the low cost VNIR spectroradiometer of choice.
使用者手冊
軟體下載
6.4.3
6.20
2.31
1.3
配件
Probes and Lighting
接触式探头
ASD 接触式探头设计用于对固体原材料(如矿物、谷物和其他颗粒材料)进行接触式测量。 其创新的光学设计最大限度地减少了与杂散光相关的测量误差,并可穿透透明塑料袋测量样品。
除了标准接触式探头外,ASD 还提供 Hi-Brite 接触式探头和植物探头。
所有接触式探头均配有坚固耐用的电缆馈线和接线,专为温度极低或极高的应用而设计。 (规格请见下图)
规格:
长度 | 10" ( 25.4 cm) |
重量 | 1.5 lbs (0.7 kg) |
电源要求 | 12-18 VDC,6.5 W |
光源类型/使用寿命(近似值) | 卤素灯泡/1500 小时 |
卤素灯泡色温 | 2900 K |
光斑大小 | 10 mm |
Hi-Brite 接触式探头
与 ASD 标准接触式探头具有相同的设计、特性和优点,但样品窗口的照明强度更高。 这种高强度照明非常适合无机分析应用,推荐在采矿和研究领域与 TerraSpec、FieldSpec 4 Hi-Res 和 LabSpec Hi-Res 光谱仪共同用于矿物和矿石的表征。
植物探头
与 ASD 的标准接触式探头具有相同的设计和功能,但灯泡亮度较低,可从活植被和其他热敏目标采集无损数据。
植物探头可以单独使用,也可以与叶夹结合使用,以保护敏感植物。
Leaf Clip
ASD's Leaf Clip assembly is designed specifically for use with the Plant Probe to simplify the process of collecting spectra on live vegetation. The unique design includes a gentle trigger lock/release gripping system for holding the target sample in place without removing the leaf from its habitat, or inflicting damage.
积分球
积分球的整个半球可从样品采集反射光。 球体由于其内部漫反射(朗伯反射)和能量积分的性质,对来自样品的定向反射特性不敏感,因此,对放置在球形端口处光束中的样品反射率给出可重复性很强的“平均”响应。 样品放置和入射光束/采集对准因素对测量结果的影响较小,因为积分球同时从各个角度查看具有代表性的平均能量。
General Accessories
手枪式握把
使用 FieldSpec® 和 FieldSpec 手持式仪器时,ASD 提供多种手枪式握把选件,可实现卓越的易用性和对各种环境和场景元素分析的适应性。 所有手枪式握把设计均包括快接/快卸式光纤电缆卡装功能、手枪式握把夹组件(可安全、牢固地将手枪式握把固定在背包的腰带上),而且很多握把还提供内置圆水平仪,以提高精确度。
Fore Optics
Equatorial mount
The Equatorial Mount is used to maintain the orientation of the Direct Irradiance Attachment (sold separately) and the Full Sky Irradiance RCR (sold separately) relative to the sun.
Once the mount is manually aligned with the Earth's rotational axis and proper solar alignment is obtained using the directional keypad, this mount scans in synchronization with the motion of the sun through the sky.
The mount is powered by a rechargeable 12 volt gel cell battery pack included with the mount. The heavy duty tripod on which the mount is installed is also included. The FieldSpec® spectrometer is mounted on a tripod (available separately). The tripod tray is not a standard item.
For use with all FieldSpec® and HandHeld models.
Reference Panels
参考面板
ASD 提供各种大小的已校准和未校准的漫反射白色与灰色参比板(尺寸从 2 x 2 in. 到 12 x 12 in., 或 5.1 x 5.1 cm 到 30.5 cm x 30.5 cm 不等)和多种反射率级别,包括封装灰阶(NIST/NRC 可追溯)波长和 USP 1119 的 USP 标准。 校准的参比板附带证书和文件,显示标准偏差和反射系数。
所有参比面板和标样板均可单独购买。 为了向客户提供更具成本效益的方法,我们在配件包中包含了特定尺寸或样式的参比板,以最大限度地兼容特定应用。
您的 ASD 销售代表将能够为您的需求提供最佳选择。