ASD FieldSpec 4 Wide-Res Field Spectroradiometer
The 3 nm VNIR, 30 nm SWIR spectral resolution of the ASD FieldSpec® 4 Wide-Res field spectroradiometer, is a cost-effective solution for the analysis of any material with broad spectral features. General vegetation analysis and water column studies are common application areas that are associated with broader spectral features. The ASD FieldSpec 4 Wide-Res field spectroradiometer can be utilized for many of the same applications as the Standard-Res model although the characterization of material with sharper spectral features will be less precise. The ASD FieldSpec 4 Wide-Res is not recommended for the analysis of materials and compounds with narrow or sharp geological spectral features in the SWIR range such as alteration mineralogy or atmospheric/gas studies.
Because of its wider optical slit the ASD FieldSpec Wide-Res field spectroradiometer delivers the best signal throughput of any ASD FieldSpec spectroradiometer. High throughput benefits measurements taken in low illumination conditions.
This instrument is available at a significantly lower price point than other ASD FieldSpec 4 models, which makes it an attractive option when budgets are tight.
In addition to being a cost-effective field spectroradiometer, the ASD FieldSpec 4 Wide-Res also functions well as a rugged, field spectrometer for accurate contact reflectance or non-solar stand-off measurements.
使用者手冊
軟體下載
6.40
6.4.4
6.4.3
6.20
4.0.1
1.20
配件
Probes and Lighting
接触式探头
ASD 接触式探头设计用于对固体原材料(如矿物、谷物和其他颗粒材料)进行接触式测量。 其创新的光学设计最大限度地减少了与杂散光相关的测量误差,并可穿透透明塑料袋测量样品。
除了标准接触式探头外,ASD 还提供 Hi-Brite 接触式探头和植物探头。
所有接触式探头均配有坚固耐用的电缆馈线和接线,专为温度极低或极高的应用而设计。 (规格请见下图)
规格:
长度 | 10" ( 25.4 cm) |
重量 | 1.5 lbs (0.7 kg) |
电源要求 | 12-18 VDC,6.5 W |
光源类型/使用寿命(近似值) | 卤素灯泡/1500 小时 |
卤素灯泡色温 | 2900 K |
光斑大小 | 10 mm |
Muglight
ASD Muglight 适用于需要测量反射率和吸光度的原材料分析场合。 可以透过玻璃样品瓶或使用 ASD 样品托盘转接头测量样品。 它独特而创新的设计最大限度地减少了与杂散光和镜面反射组件有关的测量误差。
对于需要更高照明亮度的用户,ASD 还提供 Hi-Brite Muglight。
Muglight 规格:
尺寸 | 5.5” x 3.7” (14cm x 9.4cm) |
重量 | 2.91 lbs (1.3 kg) |
电源要求 | 输入功率 5.5 W,灯泡 4 W |
光源(类型/使用寿命)约为 | 石英卤素钨灯 b/1500rs |
灯泡色温 | 2900 K |
光斑大小 | 12 mm |
转台
当您的应用需要分析不规则形状或非均质样品时,ASD 转台非常适合获得高度精确的平均值。 这对于谷物、农作物、纸浆和纸张、食品、塑料和采矿行业的仪器所有者尤其有用。
转台提供:
- 53.2 mm 的采样点尺寸
- 以 22 RPM 转速旋转
- 最大可容纳 150mm 的样品盘
- 占地面积小(8"x11"x11" 或 20.32 cm x 27.94 cm x 27.94 cm)。
转台标配一个 4000 小时卤素光源和一个 150 mm x 15 mm 的培养皿。
植物探头
与 ASD 的标准接触式探头具有相同的设计和功能,但灯泡亮度较低,可从活植被和其他热敏目标采集无损数据。
植物探头可以单独使用,也可以与叶夹结合使用,以保护敏感植物。
Leaf Clip
ASD's Leaf Clip assembly is designed specifically for use with the Plant Probe to simplify the process of collecting spectra on live vegetation. The unique design includes a gentle trigger lock/release gripping system for holding the target sample in place without removing the leaf from its habitat, or inflicting damage.
积分球
积分球的整个半球可从样品采集反射光。 球体由于其内部漫反射(朗伯反射)和能量积分的性质,对来自样品的定向反射特性不敏感,因此,对放置在球形端口处光束中的样品反射率给出可重复性很强的“平均”响应。 样品放置和入射光束/采集对准因素对测量结果的影响较小,因为积分球同时从各个角度查看具有代表性的平均能量。
光纤照明灯
光纤照明灯是一种便携式外部光源,设计用于没有内置光源的 ASD 仪器和采样附件。
技术规格
长度 | 11.43 cm (4.5 in.) |
宽度 | 8.255 cm (3.25 in.) |
重量 | 292 克(10.3 盎司) |
General Accessories
手枪式握把
使用 FieldSpec® 和 FieldSpec 手持式仪器时,ASD 提供多种手枪式握把选件,可实现卓越的易用性和对各种环境和场景元素分析的适应性。 所有手枪式握把设计均包括快接/快卸式光纤电缆卡装功能、手枪式握把夹组件(可安全、牢固地将手枪式握把固定在背包的腰带上),而且很多握把还提供内置圆水平仪,以提高精确度。