See the current Morphologi range . Learn more

Learn more

Morphologi 4

Morphologi 4는 정적 영상 분석 기술을 통해 입자 시료의 형태학적 특성을 상세히 제공하므로 시료와 프로세스에 대한 이해도를 높일 수 있습니다.  또한, 시험 응용 분야 조사를 위한 R&D 도구나 견고한 사용자 독립적 결과와 검증을 필요로 하는 자동 QC 분석 도구로도 이용할 수 있습니다.

카달로그 다운로드
지원팀 연락처

사용자 매뉴얼

소프트웨어 다운로드

08 November 2023

10.34

Reverting to a previous driver version and improving the robustness of the image capture code and ability to restart an unresponsive camera to maintain ESD compliance.

10.34

11 August 2021

10.32

Version 10.32 fixes 2 critical bugs, the audit trail files are now protected from accidental modification and manual light

setting measurements which were prevented by v10.31 can be run again.

10.32

02 December 2020

10.31

This release improves the Installation Qualification (IQ) process with new Performance Verification (PV) and system

check reports for Morphological and ID components. Stability and security have also been

improved with new camera drivers and restrictions on custom calculation functionality.

10.31

23 June 2020

10.30

Improved spectral performance

  • Addition of option to collect a background spectrum at start of measurement. This feature improves the user’s workflow as it ensures a background spectrum is collected from the actual sample being analyzed at the start of the measurement process, preventing the possibility of an incorrect background being used.
  • Improvements to the Raman Spectra signal to noise when acquisition time is 2 minutes or longer.
10.30

12 February 2020

10.21

  • Enable full software functionality with non-English PC language settings (tested on English & French and verified on German and Japanese locales).
10.21

18 March 2019

10.20

  • 21 CFR Part 11 support
10.20

06 July 2018

10.10

  • Morphologi 4-ID instrument support
10.10

22 March 2018

10.00

  • Morphologi 4 instrument support
  • Windows 10
10.00

이벤트 및 교육

모든 이벤트
Webinar - Recorded
Morphologi 4 Demo

June 2022 | English

Morphologi 4 Demo

제품:
Morphologi 4, Morphologi 4-ID
기술 유형:
동적 영상 분석, Morphologically Directed Raman Spectroscopy (MDRS), 정적 영상 분석
산업:
제약
Morphologi 4 Demo
Webinar - Recorded
Everything pharmaceutical scientists need to know about solid form characterization Part 3

November 2021 | English

Everything pharmaceutical scientists need to know about solid form characterization Part 3

제품:
Aeris range, Empyrean range, Mastersizer 3000, Morphologi 4
기술 유형:
X-ray Scattering, X-ray Diffraction (XRD), 레이저 회절, Morphologically Directed Raman Spectroscopy (MDRS), 시차 주사 열량측정법(DSC)
산업:
제약, 의약품 제형 개발, 신약 개발
Everything pharmaceutical scientists need to know about solid form characterization Part 3