Additives - elemental concentration | XRF | Additive elements in plastics and polyolefinic polymers, | Zetium - Analysis of additives in polymers using ADPOL |
Additives - elemental concentration | XRF | Additives in polyethylene | Analysis of additives in polyethylene using the ADPOL standards |
Block copolymers - impurity detection | GPC | Block copolymer of poly(ethylene glycol) (PEG) and poly(lactic acid) (PLA) PEG-b-PLA, | The detection of impurities in block copolymers |
Block copolymers - intrinsic velocity and molecular weight | GPC | Polystyrene block with polybutadiene block or polyisoprene block | FIPA of block copolymers (SBS and SIS) |
Copolymers - backbone modification | GPC | Methyl methacrylate-based copolymer structure | Backbone modification - polymer structure analysis |
Copolymers - branching and molecular weight | GPC | Linear copolymer (low branching-, medium branching-, high branching) in THF | Characterization of branched copolymers by triple detection GPC |
Elastomers - intrinsic velocity and molecular weight | GPC | Ethylene-Propylene-Diene-Monomer (EPDM) elastomers in cyclohexane | FIPA of EPDM elastomers |
Fluro-polyester - intrinsic viscosity and molecular weight | GPC | Fluoro-polyester (PMTFMA) in acetone and THF | Solvent Enhanced Light Scattering (SELS) of Fluoro-Polyester |
Medical Polymers - cleaving and molecular weight reduction | GPC | Medical-grade polymethyl methacrylate (PMMA) | Effects of gamma-ray sterilization on high molecular weight PMMA for biomedical applications |
Nitrile Rubbers - hydrodynamic radius, intrinsic viscosity, and molecular weight | GPC | Acrylonitrile-butadiene copolymers (NBR) | Triple Detection of Nitrile rubbers |
Nylon - intrinsic viscosity and molecular weight | GPC | Nylon in Formic Acid | GPC Characterization of Nylon using Formic Acid for Reduced Cost per Analysis |
Phenolic resins - molecular weight, coiling, and branching | GPC | Phenol formaldehyde resins | Characterization of modified phenolic resins |
Poly(N-isopropylacrylamide) - polymer size vs temperature | DLS | Poly(N-isopropylacrylamide) (PNIPAM) | Automated size and intensity trend measurements |
Polyacrylamide - molecular weight and size | GPC | Polyacrylamide (PAAm) | Triple detection GPC of high molecular weight polyacrylamide |
Polycaprolactone - low molecular weights | GPC | Polystyrene, polycaprolactone, in THF | Enhanced resolution of low molecular weight samples using Advanced Polymer Chromatography (APC) in combination with advanced multi-detection |
Polymer analysis by XRF - sample preparation | XRF | Polymer granules, chips, and powders | Compression molding of polymer samples for XRF analysis |
Polymer degradation - molecular weight | GPC | Poly(lactic acid) (PLA) degradation with grinding and printing | GPC/SEC Analysis of Polymer Degradation |
Polymers - introduction to DLS | DLS | Polystyrene, Poly(N-isopropylacrylamide) (PNIPAM), | Characterization of polymers using light scattering techniques |
Polymers – Advanced Polymer Chromatography | GPC | NIST Polystyrene Standards, | Combining advanced polymer chromatography with advanced detection for complete polymer characterization |
Polymers - introduction to GPC | GPC | Polymers generally | Determination of polymer structure by GPC |
Polymers - measurement accuracy by GPC | GPC | Polystyrene (PS), polymethyl methacrylate (PMMA), polyvinylchloride (PVC) | How to maximize absolute molecular weight measurement accuracy: synthetic polymers |
Polystyrene - branching and molecular weight | GPC | Polystyrene (PS) | Universal calibration to study star-branched polystyrene |
Polystyrene - branching and molecular weight | GPC | Polystyrene (PS) | Differentiation of polymer branching and composition using the Mark–Houwink plot |
Polystyrene - structure definition, branching | GPC | Polystyrene in Tetrahydrofuran (THF) | Using multi-detector Advanced Polymer Chromatography (APC) to better differentiate samples by structure |
Polythiophenes - intrinsic viscosity and molecular weight | GPC | Polythiophenes in THF | GPC of polythiophene |
PS and PMMA - blend analysis | GPC | Polystyrene (PS) and polymethyl methacrylate (PMMA) | Polymer blend analysis by GPC-PDA |
PS and PMMA - introduction to GPC | GPC | Polystyrene (PS) and poly(methyl methacrylate) (PMMA) | How to use GPC/SEC for compositional analysis |
PTFE - Zeta potential | ELS | Polytetrafluoroethylene (PTFE), polycarbonate | The influence of ionic strength on surface zeta potential |
PTFE - Zeta potential | ELS | Polytetrafluoroethylene (PTFE) surface | Determination of the zeta potential of the surface of PTFE |
PTFE and Latex - Zeta potential | ELS | Polytetrafluoroethylene (PTFE) surface and latex particles in 1mM NaCl | Measuring Surface Zeta Potential using the Surface Zeta Potential Cell |
Purity - elemental analysis | XRF | Cr, Cd, Br, Hg, and Pb in polyolefin polymers | ROHS-3/WEEE/ELV analysis of polyolefins in accordance with ASTM F2617-15 |
Residues - elemental analysis | XRF | Na, Mg, Al, Si, P, S, Ca, Ti, and Zn catalyst residues in polymers | Analysis of additives and catalyst residues in polyethylene using ADPOL standards |
Residues - elemental analysis | XRF | Mg, Al, P, Ca, Ti, and Zn in polymers | Zetium - Trace element analysis of Mg, Al, P, Ca, Ti and Zn in polymers using Zetium |
PET resins - solution viscosity | GPC | Polyester terephthalate (PET) resins in two solvents, o-chlorophenol (OCP) and 3:2 Phenol:TCE | Dilute solution viscosity of polyethylene terephthalate (PET) |
Thermoplastics - elemental analysis | XRF | Thermoplastics | Zetium - Proficiency testing for elemental analysis of thermoplastics according to ASTM D6247 using ADPOL and TOXEL |
Toxic elements - elemental concentrations | XRF | Lead, cadmium, mercury, chromium, and bromine in PVC polymers | Polymer analysis in accordance with ASTM F2617-08 using PVC Calibration standards |
Toxic elements - elemental concentrations | XRF | Cr, Ni, Cu, Zn, As, Br, Cd, Ba, Hg, and Pb in polyolefins (PE and PP) | Zetium - Analysis of toxic elements (Cr, Ni, Cu, Zn, As, Br, Cd, Ba, Hg and Pb) in polymers using TOXEL standards |