See the current NanoSight range . Learn more

Learn more

NanoSight LM10

Das Malvern Panalytical NanoSight LM10 Instrument bietet eine einfach zu bedienende Plattform für die reproduzierbare Charakterisierung von Nanopartikeln.

Das LM10 ermöglicht die schnelle, genaue Analyse der Größenverteilung und Konzentration aller Typen von Nanopartikeln im Größenbereich von 20 nm bis 1.000 nm Durchmesser (abhängig von der Gerätekonfiguration und dem Probentyp).

Support kontaktieren

Benutzerhandbücher

Software-Downloads

05 October 2020

3.44

Capture

    • USB camera support.

Other

    • Improved logging. Instrument log files will no longer be overwritten at the start of each day.

    • Improved handling of corrupt/unreadable video files.

    • New script command for automated/unattended data export.

    • Resolved HASP issues in Windows 10 (Version 2004)

3.44

08 January 2019

3.40

Improvements including:

  • USB camera support
  • Improved logging
  • Improved handling of video files
  • New script commands for data export
3.40

27 July 2018

3.30

Improvements including:

  • New SOP pages
  • CFR
3.30

27 November 2015

3.20

Improved Automation

  • Auto-setup, auto-level, focus-level, and auto-focus script commands available
  • Script command to change experiment filename
  • Make background script commands added
  • Changes to continuous flow SOP scripts to ensure smooth flow

Exports

  • Laser color added to nanolog.csv and other outputs

Interface changes

  • Run button on Recent Measurements page
  • User direction messages for capture and process settings improved
  • User Positions 1 and 2 removed

Additional features

  • Optional CFR feature available – audited operation, secure login, data integrity checking, user level program configuration
  • CFR feature can be enabled by adding feature code to CFR security dongle
  • The CFR feature is available as a chargeable upgrade – Part No. PSS0054 for new builds, Part No. NTA4165 as an upgrade for customers running NTA 3.2 software

Other

  • Extended camera log for diagnostic purposes, can revert to daily usage via nano.ini
3.20

15 June 2015

3.10-I2

Improvements and Features

  • Concentration measurement upgrade option for NS500 and single and multi-laser NS300

Improved Automation

  • Automatic focus available for NS300 and NS500
  • Automatic camera level for all instruments

Data Display and Manipulation

  • Flexible data overlays for line graphs and scatter plots
  • CSV and PDF export options for overlaid data
  • Ability to report concentrations between specific size limits
  • Option to ‘exclude’ regions of particles from the scatter plot
  • Updated display for zeta plots

Interface changes

  • Quick access to recent experiments through dedicated tabbed window
  • Experiments display overlaid graphs and scatterplots on load
  • Improved flexibility and usability for graph settings
  • Filter wheel has its own hardware tab, with customisable buttons
  • Procedure guide for electrode air removal
  • Warnings to remind user of essential hardware checks/maintenance

Additional improvements

  • Refined camera levels to give more suitable settings for brighter particles
  • Refined detection threshold range
  • Speed optimised size distribution algorithm runs up to 20 times faster
  • Refined focus and stage controls for ease-of-use
  • Option to correct viscosity and dilution after making a measurement
  • Improved hardware auto-detection and reconnection menus
3.10-I2

30 March 2015

3.10-I1

Improvements and Features

  • Concentration measurement upgrade option for NS500 and single and multi-laser NS300

Improved Automation

  • Automatic focus available for NS300 and NS500
  • Automatic camera level for all instruments

Data Display and Manipulation

  • Flexible data overlays for line graphs and scatter plots
  • CSV and PDF export options for overlaid data
  • Ability to report concentrations between specific size limits
  • Option to ‘exclude’ regions of particles from the scatter plot
  • Updated display for zeta plots

Interface changes

  • Quick access to recent experiments through dedicated tabbed window
  • Experiments display overlaid graphs and scatterplots on load
  • Improved flexibility and usability for graph settings
  • Filter wheel has its own hardware tab, with customisable buttons
  • Procedure guide for electrode air removal
  • Warnings to remind user of essential hardware checks/maintenance

Additional improvements

  • Refined camera levels to give more suitable settings for brighter particles
  • Refined detection threshold range
  • Speed optimised size distribution algorithm runs up to 20 times faster
  • Refined focus and stage controls for ease-of-use
  • Option to correct viscosity and dilution after making a measurement
  • Improved hardware auto-detection and reconnection menus
3.10-I1

15 July 2014

3.0

Improvements and Features
  • Redesigned interface, focusing around repeat measurements
  • Improved particle size distribution algorithm
  • Automatic, integrated hardware detection and communication
  • Increased compatibility with networked computers
  • Easy setup with new installer package
  • Additional features
  • New file system with less files per experiment
  • Improved particle detection and tracking
  • Improved vibration correction
  • Settings stored in the registry rather than .ini file
3.0

14 October 2024

1.2

  • Maintenance including improved tracking algorithms

See SUN for more details.

1.2

23 February 2024

1.1

  • Project export and import
  • General workflow and existing feature improvements
  • Improved robustness for fluorescence measurements
  • Minor bug fixes

See SUN for more details.

1.1

10 May 2023

1.0

NanoSight Software Activation Tool v1

1.0

14 September 2023

1.0

NS Xplorer is the software for the NS Pro instrument

  • 1st Release
1.0

Zubehör

NanoSight Spritzenpumpe

Die Malvern Panalytical NanoSight Spritzenpumpe ist für alle Malvern Panalytical NanoSight Systeme erhältlich und ermöglicht den Benutzern, Probenanalysen bei konstanter Flussrate durchzuführen, für eine verbesserte Probenstatistik und Messung von photobleichenden fluoreszierenden Proben.

Veranstaltungen und Schulungen

Alle Events
Webinar - Recorded
Physicochemical Characterization of Nanomedicines: Investigating surface characteristics of nano delivery systems and their interactions with plasma

January 2021 | English

Physicochemical Characterization of Nanomedicines: Investigating surface characteristics of nano delivery systems and their interactions with plasma

Produkte:
Zetasizer Advance Range, NanoSight LM10
Technologie:
Lichtstreuung, Statische Lichtstreuung, Dynamische Lichtstreuung
Industrie:
Biologika, Pharmazie, Nanomaterialien
Physicochemical Characterization of Nanomedicines: Investigating surface characteristics of nano delivery systems and their interactions with plasma

Servicevertrags-Optionen

Mit den Malvern Panalytical Service-Verträgen sichern Sie sich die langfristige und optimierte Funktionsfähigkeit Ihrer Analysegeräte.

Der Kauf eines Malvern Panalytical-Produkts ist für uns erst der Beginn einer langjährigen Geschäftsbeziehung über die gesamte Lebensdauer des Gerätes, die Malvern Panalytical entsprechend Ihrem individuellen Bedarf gerne mit seinen Services unterstützt.

Help Desk

Schulungen

  • Anwenderschulungen

Software-Downloads

Die Malvern Panalytical Service-Verträge – wählen Sie die passende Option für Ihren Bedarf:

Malvern Panalytical Platin Service-Vertrag

Für Labore bei denen die Geräte-Verfügbarkeit für die tägliche Arbeit kritisch ist. Der all-inclusive Vertrag sichert kürzeste Reaktionszeiten zu und deckt alle Wartungskosten, aber auch unerwarteten Reparaturkosten ab.

Malvern Panalytical Gold Service-Vertrag

Stellen Sie die Produktivität Ihres Labors durch die regelmäßige Wartung Ihres Systems sicher und erhalten Sie einen schnellen, spezialisierten und kompetenten Support im Störungsfall.

Malvern Panalytical Bronze Service-Vertrag

Für Labore die eine einmalige vorbeugende Wartung oder Support-Leistung wünschen.

Platin VertragGold VertragBronze Vertrag
Jährliche Wartung und Verifizierung
Ja
Ja
Nein
Telefon / E-Mail Support
Ja
Ja
Nein
Fixe Reaktionszeiten
Ja
Ja
Nein
Notfall-Besuch im Störungsfall*
Ja
Ja
Nein
Ersatzteile inklusive
Ja
Nein
Nein
Technik & Software Support
Ja
Ja
Ja
IQ/OQ (Pharma)***
Ja
Ja
Ja

*inklusive Arbeits- und Anfahrtskosten***gegen geringen Aufpreis möglich

Support kontaktieren