Determination of chloride ion concentrations in concrete by means of near-infrared spectrometry

Concentration of chloride ions was determined with a classical chemical titration method in three types of samples: a cracked concrete core and an undamaged concrete core, both taken from a bridge in Iowa, and also from concrete test samples prepared at Rutgers University. Chloride concentration profiles were obtained. The same samples were the subjected to the near infrared spectrometric determinations of chloride content by two manufacturers of spectrometric instruments. Very good correlation between the chemical and spectrometric measurements was obtained [ R2> 0.96], thus opening the possibility of rapid on-site chloride concentration determination in concrete structures.