Academia Grant Program: dollar-for-dollar and up to $30K grants for our flagship instruments. Apply by December 15, 2025. Apply now

Apply now

Zetasizer Advance Range

Light Scattering for every application

Download brochure

Zetasizer Advance is the successor to the highly successful and market-leading Zetasizer Nano.

Each of the three models in the Zetasizer Advance Range offers particle size, particle charge (zeta potential) and molecular weight analysis. In addition, each benefits from advances including Adaptive Correlation, M3-PALS zeta potential analysis, constant current zeta mode and our deep learning-based data quality advice system.

Each of the three models is available as a Blue Label or Red Label variant:

  • Choose Blue Label for routine sample investigation such as metallic colloids, metal oxides and pigments
  • Choose Red Label for more challenging sample types, such as proteins, surfactant solutions and low solid content samples

Find your perfect Zetasizer

All Zetasizer Advance systems offer on-site upgradeability with minimal downtime. Should your needs change, your Zetasizer can adapt to new challenges.

Om_logo.png  Works with OmniTrust: Malvern Panalytical's compliance solution for the regulated environment

Zetasizer Ultra

Our most advanced system for the measurement of particle and molecular size, particle charge and concentration.

Features include

  • Classic 90° DLS
  • Static light scattering
  • Non-Invasive Back Scatter DLS
  • Multi-Angle Dynamic Light Scattering
Zetasizer Ultra

Zetasizer Pro

The Zetasizer Pro is your go-to instrument to measure a wide range of sample types and concentrations.

Features include

  • Classic 90° DLS
  • Static light scattering
  • Non-Invasive Back Scatter DLS
  • Multi-Angle Dynamic Light Scattering
Zetasizer Pro

Zetasizer Lab

The Zetasizer Lab is an entry-level system that employs classical 90° sizing with advanced features.

Features include

  • Classic 90° DLS
  • Static light scattering
  • Non-Invasive Back Scatter DLS
  • Multi-Angle Dynamic Light Scattering
Zetasizer Lab
Zetasizer Ultra

Zetasizer Ultra

World’s most advanced light scattering system

Zetasizer Pro

Zetasizer Pro

High performance, versatile and robust

Zetasizer Lab

Zetasizer Lab

Classic side scatter particle size and zeta potential analyzer with enhanced capabilities

Technology
Classic 90° DLS
Non-Invasive Back Scatter DLS (NIBS)
Multi-Angle Dynamic Light Scattering (MADLS)
Static light scattering
Size range 0.3 nm to 10 μm 0.3 nm to 10 μm 0.3 nm to 10 μm
Minimum volume 3 μL 12 μL 3 μL
Measurement type
Zeta potential
Molecular weight
Particle concentration / titer Red Label only
21 CFR part 11 compliant software Optional Optional Optional
Zeta potential size range 3.8 nm to 100 μm 3.8 nm to 100 μm 3.8 nm to 100 μm

The instrument helps to characterize the size and zeta potential of the nano materials that is synthesized. Instrument can be handled with great ease and it is user friendly. The results can be directly evaluated and saved.

Arun Varghese — Christ University