Zetasizer Nano smart install guide (English)
Version number: MAN0383-06-EN
New Zetasizer Advance – DLS for every application – meet the new Zetasizer Family!. Find out more
Find out moreThe much acclaimed Zetasizer Nano range ended sale in November 2020, and Malvern Panalytical will continue to provide our customers with aftercare support for the Zetasizer Nano product family for up to seven years from the end of sale.
Malvern Panalytical continue to offer Dynamic Light Scattering and Zeta Potential measurement systems and further strengthen our leadership in scientific instrumentation with the Zetasizer Nano’s successor, the new Zetasizer Advance range.
Version number: MAN0383-06-EN
Version number: MAN0486-02-EN
Version number: MAN0318-4-0
Version number: MAN0485-1-1
Version number: MAN0487-2-0
Version number: MAN0497-01--EN-00
The Zetasizer NanoSampler is a sample delivery system that ensures highly precise and reproducible automated loading of samples into your Zetasizer Nano. The NanoSampler adds automation and unattended operation in a versatile, compact package, maximising the productivity of your Zetasizer Nano. While the benefits of automated operation are useful for all users, the NanoSampler is ideally suited for laboratories where a large number of measurements are required and reproducibility or multi-variate studies are important.
A cost effective accessory designed to automate the measurement of size and zeta potential as a function of pH, conductivity or any soluble additive.
The SV-10 measures viscosity with the accuracy required for dynamic light scattering, for the conversion of diffusion speed to size, and electrophoretic mobility to zeta potential, in an extremely simple and rapid system.
Titrants used by the MPT-2 titrator need regular degassing, ideally before each titration.
Degassing is required to remove bubbles that can affect the volume of titrant dispensed. This is particularly important close to pH 7 where low volumes of titrant are required.
The degasser is a highly recommended ‘Fit and forget’ accessory that continuously degasses titrants which improves the speed of titrations and the accuracy of reaching the target pH. This gives more evenly spaced pH points.
Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.
When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.
For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.
Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.
For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.
Platinum Plan | Gold Plan | Bronze Visit | |
---|---|---|---|
Annual PM/PV Test | yes | yes | no |
Telephone / Email Support | yes | yes | no |
Priority Response | yes | yes | no |
Emergency Breakdown visits* | yes | yes | no |
Parts Included | yes | no | no |
E-Learning** | yes | yes | no |
Technical & Software Support | yes | yes | yes |
IQ/OQ (Pharma)*** | yes | yes | yes |
*including labour & travel costs** Platinum 2 places per contract term, Gold 1 place per contract term***available at an additional cost